Electrical trade estimating
Fire Alarm Estimating Services
Detailed fire alarm estimates covering control panels, initiating devices, notification appliances, voice evacuation, monitoring, cabling, programming and testing, priced to NFPA 72 and Florida requirements.
- Device counts by type and location
- Addressable and voice evacuation systems
- Programming, testing and inspection included
Free quote
Send plans. Get a firm quote.
- Quote back after a quick plan review
- Typical delivery in 24–48 hours
- Excel estimate + marked-up drawings
- Priced to Florida labor and material rates
Or email ask@floridamepestimating.com
24–48 hr typical turnaround
NDA-protected plans
Florida Building Code aware
Florida labor & material pricing
Overview
Every device, every circuit, every hour of programming
Fire alarm systems are made up of hundreds of devices spread throughout a building: smoke and heat detectors, pull stations, duct detectors, horns and strobes, speakers, monitor and control modules. Each one needs wiring, mounting and programming, and the life-safety stakes mean inspectors check them closely.
We count devices by type and location from the fire alarm drawings or, where those don’t exist yet, lay out a system based on the architectural plans and the applicable codes. Cabling is measured by circuit type, and panels, power supplies, batteries, monitoring and programming are priced. Testing, inspection and documentation are included.
Fire alarm can be estimated on its own or as part of an electrical estimate or a full fire protection package with fire sprinklers.
What's included
Fire alarm scope we take off
- Fire alarm control panel and annunciators
- Smoke, heat and duct detectors
- Manual pull stations
- Horns, strobes, speakers and speaker-strobes
- Monitor, control and relay modules
- Sprinkler flow and tamper switch connections
- Elevator recall and HVAC shutdown interfaces
- Door holders and access control release
- Voice evacuation and mass notification
- Power supplies, batteries and NAC extenders
- Fire alarm cable, conduit and pathways
- Programming, testing, inspection and as-builts
Florida factors
Fire alarm requirements in Florida
Florida’s Fire Prevention Code and local fire marshals drive fire alarm requirements, and Florida’s high-rise, hotel, healthcare and multifamily buildings often need voice evacuation, firefighter communication and two-way communication systems. In-building emergency responder radio coverage (ERRCS) is also required in many new buildings, which adds a separate low-voltage scope.
Older condo and apartment buildings are another big source of fire alarm work, as associations upgrade aging systems during renovations and life-safety improvements. We price retrofits with the extra labor that comes with occupied buildings, existing finishes and phased cutovers.
At a glance
Device count summary example
| Device | Unit | Where counted |
|---|---|---|
| Smoke detectors | Each | Corridors, rooms, elevator lobbies |
| Horn/strobes | Each | All occupied areas per coverage |
| Pull stations | Each | Exits and stairs |
| Modules | Each | Sprinkler, HVAC, elevator, door interfaces |
| Cable | Linear feet | By SLC, NAC and speaker circuits |
Scope gaps we catch
Fire alarm gaps we catch
Fire alarm budgets miss interfaces with other systems. We price items like these.
- Duct detectors on air handlers and their remote test stations
- Elevator recall and shunt trip interfaces
- Door holder and access control release modules
- NAC extender panels for large horn/strobe loads
- Monitoring contract setup and communicator
- Programming, testing and AHJ inspection time
Our process
How our MEP estimating process works
- 01
Send your plans
Upload PDFs, CAD files or a bid-portal link with specs, addenda and the bid date. A quick scope note helps.
- 02
Get a fixed quote
We confirm scope, price and delivery date before any work starts. No surprises on the invoice.
- 03
Takeoff & pricing
Estimators count and measure every MEP item, then price labor and material for the project's Florida location.
- 04
Senior QA review
A second estimator checks quantities, scope gaps and math against the drawings and specs.
- 05
Bid-ready delivery
You get the Excel estimate, marked-up drawings and a clarifications list you can send with your bid.
FAQs
Frequently asked questions
Straight answers to what contractors usually ask before sending plans. Don’t see your question? Call or email us.
Can you estimate without fire alarm drawings?
Yes. We lay out a code-based system from the architectural plans and list our assumptions. The final design may change device counts.
Do you include programming?
Yes. Programming, testing, inspection and documentation are included.
Do you price voice evacuation systems?
Yes, including amplifiers, speakers, microphones and firefighter phones where required.
Is ERRCS (emergency responder radio) included?
ERRCS is usually a separate scope. We can price it on request based on a radio coverage design or allowance.
Do you estimate fire alarm retrofits?
Yes, including demolition, new devices, cutover planning and occupied-building premiums.
What's the turnaround?
Most fire alarm estimates are delivered within 24 to 48 hours.
Keep exploring
Related estimating services
Estimating services
MEP trades
Have plans on your desk? Get your MEP number before the bid date.
Send the drawings today and we will confirm price and delivery before any work starts.
Start here
Get a free MEP estimating quote
Upload your drawings and tell us what you need. We review the plans, confirm scope and send a price and delivery date. Your files stay confidential.
- Call1 (816) 683-1595
- Office349 State Ln, Orlando, FL 32801